国偷自产一区二区三区在线视频,日本国产精品一区二区,午夜无码大尺度福利视频,人妻丰满熟妇av无码区hd,欧美午夜刺激影院,99热成人精品热久久66,欧美喷潮系列在线观看,国产视频毛片
                歡迎來北京祥生興業科技有限公司!我們將為您提供周到的服務!
                首頁 > 產品中心 > 臨床質譜質控品、校準品 > Chromsystems > Vitamin C in Plasma/Serum - HPLC

                產品名稱:Vitamin C in Plasma/Serum - HPLC

                產品型號:65065

                產品報價:

                產品特點:

                英文名:VitaminCinPlasma/Serum-HPLC供應商:祥生興業規格:100TestsVitaminCinPlasma/Serum-HPLCOrderno

                免費咨詢:13681184382

                發郵件給我們:702140183@qq.com

                分享到:

                65065Vitamin C in Plasma/Serum - HPLC的詳細資料:

                溫馨提示:僅用于科研,不可用于臨床治療

                • 英文名:

                  Vitamin C in Plasma/Serum - HPLC

                • 供應商:

                  祥生興業

                • 規格:

                  100 Tests

                  Vitamin C in Plasma/Serum - HPLC


                  Order no.: 65065
                  100 Tests
                  • Vitamin C

                  Simplified sample preparation
                  Enhanced column stability
                  High stability of standards and controls

                  DESCRIPTION

                  Clinical relevance

                  Vitamin C (ascorbic acid, ascorbate) is a water-soluble vitamin that is an essential cofactor for the human body, for instance in the catabolism of tyrosine and the synthesis of catecholamines. Regular consumption of fruit and vegetables is usually sufficient to cover the body’s vitamin C needs.

                  In the case of vitamin C deficiency, procollagen chains are produced insufficiently and stable fibrils cannot be formed in the affected cells. Without functioning collagen, the blood vessels and tendons become fragile and the typical skin-related symptoms associated with scurvy start to develop. In addition to the collagen damages described above, further diseases caused by vitamin C deficiency include bleeding of uncertain origin, loss of teeth and overactive thyroid gland (hyperthyroidism). Vitamin C deficiency is also observed in dialysis patients, in chronic alcohol abuse and during pregnancy.

                   

                  Product advantages

                  • High stability of processed samples and controls
                  • Enhanced column stability
                  • Reliable quantification with a stable internal standard

                   

                  This Chromsystems kit allows the reliable chromatographic determination of vitamin C in one isocratic HPLC run with UV detection. An efficient protein precipitation step removes interfering components and stabilises Vitamin C simultaneously. A stable internal standard is used for reliable quantification. Due to a special stabilisation of the prepared samples, it is also possible to reliably process and measure large sample batches.

                   

                   

                  CHROMATOGRAM

                  65065 HPLC kit vitamin C plasma serum - Chromatogramm EN

                  TECHNICAL DATA

                  Method of Analysis

                  HPLC

                  Number of Tests

                  100

                  Parameter

                  Vitamin C

                  Analysis Time

                  5 min

                  Limit of quantification

                  0.4 mg/l

                  Linearity

                  0.4–100 mg/l

                  Recovery

                  97–103 %

                  Intraassay

                  CV ≤ 3.8 %

                  Interassay

                  CV ≤ 4.8 %

                  Specimen

                  Plasma/Serum

                  Pre-analytic Treatment

                  Fresh lithium heparin plasma is used for analysis. To minimise the oxidation of vitamin C the whole blood sample should be centrifuged immediately after collection and the plasma samples must then be transported deep frozen. Start sample preparation immediately after thawing. The stability for vitamin C in heparin plasma is 5 days at -20 °C. At room temperature this is only up to two hours. If whole blood is used for transportation, store at +2 to +8 °C , do not freeze.

                  Sample Preparation

                  • Pipette 100 μl sample/calibrator/control into a labelled light protected reaction vial.

                  • Add 100 μl Internal Standard and mix 30 s (vortex).

                  • Centrifuge 5 min at at least 13000 x g.

                  • Inject 20 μl of the supernatant into the HPLC system.

                  Sample Stability

                  The patient samples are stable for 12 h at room temperatur, at +2 to +8 °C for at least 2 weeks. For longer storage (up to 6 weeks) keep samples below -18 °C.

                  Additional Info

                  Any isocratic HPLC system with UV detection is suitable.

                   

                  Injection Volume

                  20 µl

                  Flow rate

                  1.5 ml/min

                  Gradient

                  Isocratic

                  Column temperature

                  ambient (~25 °C)

                  Wavelength

                  245 nm

                  Please note

                  The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals.

                  KIT COMPONENTS

                  Components available separately

                  Mobile Phase


                  Order no.: 65001

                  DETAILS

                  Mobile Phase, 10 x 1000ml


                  Order no.: 65002

                  DETAILS

                  Internal Standard


                  Order no.: 65044

                  DETAILS

                  Reaction vials


                  Order no.: 33005

                  DETAILS

                  Vitamin C Plasma Calibration Standard


                  Order no.: 65003

                  DETAILS

                  ACCESSORIES

                  PEEK prefilter housing


                  Order no.: 15010

                  DETAILS

                  HPLC column


                  Order no.: 65100

                  DETAILS

                  PEEK-encased prefilter, 5 µm


                  Order no.: 15009

                  DETAILS

                  Precolumn cartridge 4/10


                  Order no.: 18065

                  DETAILS

                  Precolumn cartridge holder 4/10


                  Order no.: 18001

                  DETAILS

                  CALIBRATORS

                  Calibrators available separately

                  Vitamin C Plasma Calibration Standard


                  Order no.: 65003

                  DETAILS

                  CONTROLS

                  Controls available separately

                  Vitamin C Plasma Controls


                   

                  DETAILS

                溫馨提示:不可用于臨床治療。
                 相關同類產品:

                留言框

                • 產品:

                • 您的單位:

                • 您的姓名:

                • 聯系電話:

                • 常用郵箱:

                • 省份:

                • 詳細地址:

                • 補充說明:

                • 驗證碼:

                  請輸入計算結果(填寫阿拉伯數字),如:三加四=7

                版權所有  ICP備案號:京ICP備2024091604號-1 管理登陸 技術支持:化工儀器網   總流量:130522  sitemap.xml

                主站蜘蛛池模板: 日本a级护士潮喷一区| 国产精品福利一区二区久久| 最近免费中文字幕大全免费版视频| 色网站免费在线观看| 制服丝袜人妻中出第一页| 久久综合精品国产一区二区三区无码 | 国内极度色诱视频网站| 国产精品女主播在线观看 | 亚洲激情一区二区三区在线| 国产精品推荐视频一区二区| 人妻夜夜爽天天天爽欧美色院 | 麻豆精品新a v视频中文字幕| 国产成品精品午夜视频| 亚洲是图一区二区视频| a√无码在线观看| 亚洲区1区3区4区中文字幕码| 国产免费久久精品99re丫y| 色婷婷综合和线在线| 99视频精品全部国产| 国产欧美激情一区二区三区| 亚洲一区二区高清精品| 本道无码一区二区久久激情| 欧洲精品一卡2卡三卡4卡影视| 日韩精品少妇无码受不了| 亚洲一区二区精品在线看| 中文字幕亚洲精品乱码在线看| 在线观看毛片av成人| 无码免费午夜福利片在线| 这里只有精品免费视频| 国产精品女同一区三区五区| 亚洲欧美国产国产一区二区| 亚洲香蕉网久久综合影视| 成人白浆一区二区三区在线观看| 久久久久成人精品免费播放网站| 97色偷偷色噜噜狠狠爱网站97| 欧美性猛交xxxx黑人| 粉嫩小少妇bwbwbw| 中国人妻沙发上喷白将av | 欧美日韩免费专区在线观看| 亚洲熟妇无码AV在线播放| 亚洲高清码在线精品av|